HWC-19P (1.5-Ton)
-Ships Free to 46 U.S. States
18,200 Btu/H Water-Cooled Unit is the perfect choice for locations where exhausting hot air is problematic or where chilled water is already circulating.
-Condensate Pump included
-Non-cooling dehumidification mode
-Removable/Washable filters
-Adjustable/directional air nozzles
-1 year warranty, 3 years on compressor
-Easy installation of optional HEPA filter kit
-Protected compressor with high/low pressure warnings
Hospitals choose water-cooled because the absence of exhaust air means no room-to-room cross contamination. Contractors choose water-cooled because access to running water is the easiest choice for many projects and additions. Vaults and secured rooms choose watercooled because putting large air ducts through the walls may be impossible where ½” water lines are acceptable. The colder the water is as it enters the machine, the more heat that water will accept before reaching exit temp, and the fewer gallons per min the machine will use. Water exiting the machine can be drained (Single-pass system), or recirculated by various types of chillers, or cooling tower systems.
HWC-19P (1.5-Ton)
-Ships Free to 46 U.S. States
18,200 Btu/H Water-Cooled Unit is the perfect choice for locations where exhausting hot air is problematic or where chilled water is already circulating.
-Condensate Pump included
-Non-cooling dehumidification mode
-Removable/Washable filters
-Adjustable/directional air nozzles
-1 year warranty, 3 years on compressor
-Easy installation of optional HEPA filter kit
-Protected compressor with high/low pressure warnings
Hospitals choose water-cooled because the absence of exhaust air means no room-to-room cross contamination. Contractors choose water-cooled because access to running water is the easiest choice for many projects and additions. Vaults and secured rooms choose watercooled because putting large air ducts through the walls may be impossible where ½” water lines are acceptable. The colder the water is as it enters the machine, the more heat that water will accept before reaching exit temp, and the fewer gallons per min the machine will use. Water exiting the machine can be drained (Single-pass system), or recirculated by various types of chillers, or cooling tower systems.
Height: 43” Width: 18” Depth: 23”
Cooling Capacity: 18,200 Btu/H, Approximately 700 sq. ft.
Water Consumption: 2.9 Gal/Min Average Through Self-Regulating Valve
Voltage Requirement: 1 Phase, 115V
Recommended Breaker: 15 Amp
Current Consumption: 12.6 Amps
Cord: 10’ 14AWG (3 core)
Plug: Nema 5-15
Refrigerant: R-410A
Min/Max Operating Conditions Cooling: 65°F / 115° F
Min/Max Operating Conditions Dehumidification: 65°F / 115° F
Unit Weight: 163lb